Content of review 1, reviewed on January 23, 2026

In this manuscript, the authors present a microphysiological liver-on-a-chip platform, designed to recreate the physiological Disse space for in vitro exploration of drug-induced hepatotoxicity. The platform features three parallel channels, with primary liver sinusoidal endothelial cells (LSECs) and HepaRGs in the side channels, separated by a porous sodium alginate hydrogel in the middle chamber. The mechanical properties of the hydrogel were tuned to mimic those of the native tissue, and the diffusive transport across the barrier was assessed with CDFA. The authors demonstrated LSEC alignment under shear flow, maintenance of hepatocyte polarization, and enhanced HepaRG function when combined with LSECs. Finally, they dosed the cultures with acetaminophen (APAP) for 72 hours and demonstrated decreased hepatic viability and functionality. The platform is interesting, but several major and minor items need to be addressed as detailed below to be suitable for publication.

Major comments:

• As mentioned by the authors, the space of Disse is a very thin layer of ECM (1 um in thickness). However, the width of the hydrogel layer separating HepaRGs and LSECs is much greater than this (~1 mm). The author should address the thickness difference and explain how their platform remains relevant for mimicking the perisinusoidal space.
• The authors provide a characterization of the hydrogel in terms of stiffness, swelling capacity, and transport of CDFA across the gel. However, the permeability of the alginate hydrogel to other metabolites, such as albumin (66.5 kDa), has not been investigated; therefore, it is unclear to what extent the hydrogel layer resembles the native tissue.
• The reported stiffness of the sodium alginate hydrogel (12.5 kPa) more closely mimics that of the fibrotic liver than that of the healthy liver (usually <4 kPa). Moreover, it is unclear how the stiffness of the hydrogel affects the HepaRGs and LSECs, as both are primarily attached to glass or PDMS surfaces, whose stiffness is orders of magnitude greater than that of native liver tissue (GPa and MPa, respectively).
• Urea secretion in panel B of Fig. 5 appears unusually stable and has much lower variability than albumin. Please check whether there is anything artifactual in the way the assays were performed.
• Why was CYP3A4 not measured over time in HepaRG +/- LSEC cultures over time using the same Glo assay as that used for the APAP dosing studies? Measuring enzymatic activity enhancement is critical for use of the platform for downstream applications.
• HepaRG are cancerous and bipotential liver cells, better than HepG2 in liver function but still cancerous. They don’t represent primary human liver cells. At the very least, the authors should discuss the pros and cons of using a cancerous cell line.

Minor comments:

• The magnitude of shear stress inside the device should be reported, in addition to the flow rate.
• In the discussion, the authors state that the chip design allowed the application of shear stress to both cell types, thereby resembling the in vivo situation. However, while LSECs are known to be subjected to shear flow, the same cannot be said for the hepatocytes, which perceive an interstitial shear flow at best.
• Since dosing with APAP was performed for 72 hours in total, the use of the term “chronic drug exposure” is inappropriate. Moreover, it is not explicitly stated in which channel of the device APAP was administered.
• All immunofluorescence images are too low magnification to verify the claims of the authors (especially for ZO-1 and MRP2 staining in HepaRGs)
• In the last part of the introduction, there seems to be a font change (size is different)
• Please correct typos, sentence structure, and be consistent with using either the present or past tense throughout the document
• Figure legends in the main document are very small and are hard to read
• There are many typos in the manuscript. Please proofread carefully.

Source

    © 2026 the Reviewer.

Content of review 2, reviewed on March 13, 2026

The authors have satisfactorily addressed all of my suggestions.

Source

    © 2026 the Reviewer.

References

    Ana, M., Antonietta, M., Zoe, T., Benoit, C., Mohamed, I. S., Nicolas, H., Sakina, B., Jean-Charles, D., Bruno, L. P. In Vitro Space of Disse Model for Exploration of Drug Induced Hepatotoxicity. Lab on a Chip.